Current article

THE CALCULATION OF INTERNAL FORCES AND DISPLACEMENTS IN FRAME-SHEARING WALL STRUCTURE UNDER THE HORIZONTAL LOADS


Li Hengsheng

DOI:10.11835/j.issn.1674-4764.1989.04.010

Received ,Revised , Accepted , Available online July 01, 2015

Volume ,1989,Pages -

  • Abstract
In general,the calculating result of a comparatively regular frame-shearing wall system in tall buildings,a 4-order differential equations are established according to the deformation-coordination of beams,columns and four boundary conditions.Then a series of formulas concerning internal forces and displacement is obtained These formulas are hyperbolic functions.This paper presents a method,which changes 4-order differential equations into 2-order and solves them by the expressions of new homogeneous solutionThen the formulas of internal forces and displacements become exponential functions By this method,the calculation is very convenient The result of suggested method agrees well with the general by comparison This paper is also applicable to buildings with some part of different height of storey or stiffness.